Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add filters








Language
Year range
1.
J. bras. pneumol ; 47(3): e20200371, 2021. tab, graf
Article in English | LILACS | ID: biblio-1250212

ABSTRACT

ABSTRACT Objective: To test the reliability, validity, and interpretability of the Brazilian version of the Clinical COPD Questionnaire (CCQ) in patients with COPD. Methods: Fifty patients with COPD completed the CCQ by interview on two occasions. At the first visit, the CCQ was administered twice, by two different raters, approximately 10 min apart; the patients also underwent spirometry and were administered the COPD Assessment Test, the modified Medical Research Council scale, and Saint George's Respiratory Questionnaire (SGRQ). At the second visit (1-2 weeks later), the CCQ was readministered. We tested the hypothesis that the CCQ total score would correlate positively with the total and domain SGRQ scores (r ≥ 0.5). Results: Of the 50 patients, 30 (60%) were male. The mean age was 66 ± 8 years, and the mean FEV1 was 44.7 ± 17.9% of the predicted value. For all CCQ items, Cronbach's alpha coefficient (95% CI) was 0.93 (0.91-0.96). To analyze the interrater reliability and test-retest reliability of the CCQ, we calculated the two-way mixed effects model/single measure type intraclass correlation coefficient (0.97 [95% CI: 0.95-0.98] and 0.92 [95% CI: 0.86-0.95], respectively); the agreement standard error of measurement (0.65 for both); the smallest detectable change at the individual level (1.81 and 1.80, respectively) and group level (0.26 and 0.25, respectively); and the limits of agreement (−0.58 to 0.82 and −1.14 to 1.33, respectively). The CCQ total score correlated positively with all SGRQ scores (r ≥ 0.70 for all). Conclusions: The Brazilian version of the CCQ showed an indeterminate measurement error, as well as satisfactory interrater/test-retest reliability and construct validity.


RESUMO Objetivo: Testar a confiabilidade, validade e interpretabilidade da versão brasileira do Clinical COPD Questionnaire (CCQ) em pacientes com DPOC. Métodos: Cinquenta pacientes com DPOC preencheram o CCQ por meio de entrevista em duas ocasiões. Na primeira visita, o CCQ foi aplicado duas vezes, por dois avaliadores, com intervalo de aproximadamente 10 min; os pacientes também foram submetidos a espirometria e aplicação do COPD Assessment Test, da escala modificada do Medical Research Council e do Saint George's Respiratory Questionnaire (SGRQ). Na segunda visita (1-2 semanas depois), o CCQ foi reaplicado. Testamos a hipótese de que a pontuação total no CCQ se correlacionaria positivamente com a pontuação total e a pontuação nos domínios do SGRQ (r ≥ 0,5). Resultados: Dos 50 pacientes, 30 (60%) eram do sexo masculino. A média de idade foi de 66 ± 8 anos, e a média do VEF1 foi de 44,7 ± 17,9% do valor previsto. Para todos os itens do CCQ, o coeficiente alfa de Cronbach (IC95%) foi de 0,93 (0,91-0,96). Para analisar a confiabilidade interavaliadores e teste-reteste do CCQ, calculamos o coeficiente de correlação intraclasse de duas vias modelo de efeitos mistos para medidas únicas (0,97 [IC95%: 0,95-0,98] e 0,92 [IC95%: 0,86-0,95], respectivamente); erro-padrão de medida do tipo concordância (0,65 para ambas); a mínima mudança detectável individual (1,81 e 1,80, respectivamente) e no grupo (0,26 e 0,25, respectivamente); e os limites de concordância (−0,58 a 0,82 e −1,14 a 1,33, respectivamente). A pontuação total no CCQ correlacionou-se positivamente com todas as pontuações no SGRQ (r ≥ 0,70 para todas). Conclusões: A versão brasileira do CCQ apresentou erro de medida indeterminado, assim como confiabilidade interavaliadores/teste-reteste e validade de construto satisfatórias.


Subject(s)
Humans , Male , Middle Aged , Aged , Pulmonary Disease, Chronic Obstructive/diagnosis , Quality of Life , Spirometry , Brazil , Surveys and Questionnaires , Reproducibility of Results
2.
J. bras. pneumol ; 46(1): e20180397, 2020. tab, graf
Article in English | LILACS | ID: biblio-1056621

ABSTRACT

ABSTRACT Objective: To test the construct validity, reliability, and measurement error of the Brazilian Portuguese-language version of the Manchester Respiratory Activities of Daily Living (MRADL) questionnaire in patients with COPD. Methods: We evaluated 50 patients with COPD, among whom 30 were men, the mean age was 64 ± 8 years, and the median FEV1 as a percentage of the predicted value (FEV1%predicted) was 38.4% (interquartile range, 29.1-57.4%). Pulmonary function and limitations in activities of daily living (ADLs) were assessed by spirometry and by face-to-face application of the MRADL, respectively. For the construct validity analysis, we tested the hypothesis that the total MRADL score would show moderate correlations with spirometric parameters. We analyzed inter-rater reliability, test-retest reliability, inter-rater measurement error, and test-retest measurement error. Results: The total MRADL score showed moderate correlations with the FEV1/FVC ratio, FEV1 in liters, FEV1%predicted, and FVC%predicted, all of the correlations being statistically significant (r = 0.34, r = 0.31, r = 0.42, and r = 0.38, respectively; p < 0.05 for all). For the reliability and measurement error of the total MRADL score, we obtained the following inter-rater and test-retest values, respectively: two-way mixed-effects model intraclass correlation coefficient for single measures, 0.92 (95% CI: 0.87-0.96) and 0.89 (95% CI: 0.81-0.93); agreement standard error of measurement, 1.03 and 0.97; smallest detectable change at the individual level, 2.86 and 2.69; smallest detectable change at the group level, 0.40 and 0.38; and limits of agreement, −2.24 to 1.96 and −2.65 to 2.69. Conclusions: In patients with COPD in Brazil, this version of the MRADL shows satisfactory construct validity, satisfactory inter-rater/test-retest reliability, and indeterminate inter-rater/test-retest measurement error.


RESUMO Objetivo: Testar a validade de construto, a confiabilidade e o erro de medida da versão em português do Brasil do questionário Manchester Respiratory Activities of Daily Living (MRADL) em pacientes com DPOC. Métodos: Avaliamos 50 pacientes com DPOC, 30 dos quais eram homens. A média de idade foi de 64 ± 8 anos, e a mediana do VEF1 em porcentagem do previsto (VEF1%previsto) foi de 38,4% (intervalo interquartil: 29,1-57,4%). A função pulmonar e limitações experimentadas durante a realização de atividades cotidianas foram avaliadas por meio de espirometria e da aplicação presencial do MRADL, respectivamente. Para a análise de validade de construto, testamos a hipótese de que haveria correlações moderadas entre a pontuação total no MRADL e parâmetros espirométricos. Analisamos a confiabilidade e o erro de medida entre avaliadores e entre teste e reteste. Resultados: Houve correlações moderadas e estatisticamente significativas entre a pontuação total no MRADL e VEF1/CVF, VEF1 em litros, VEF1%previsto e CVF%previsto (r = 0,34, r = 0,31, r = 0,42 e r = 0,38, respectivamente; p < 0,05 para todas). No tocante à confiabilidade e ao erro de medida para a pontuação total no MRADL entre avaliadores e entre teste e reteste, respectivamente, foram obtidos os seguintes valores: coeficiente de correlação intraclasse de duas vias e efeitos mistos para medidas únicas = 0,92 (IC95%: 0,87-0,96) e 0,89 (IC95%: 0,81-0,93); erro-padrão de medida do tipo concordância = 1,03 e 0,97; mínima mudança detectável no indivíduo = 2,86 e 2,69; mínima mudança detectável no grupo = 0,40 e 0,38; limites de concordância = −2,24 a 1,96 e −2,65 a 2,69. Conclusões: Em pacientes com DPOC, a versão brasileira do MRADL apresenta validade de construto satisfatória, confiabilidade interavaliadores/teste-reteste satisfatória e erro de medida interavaliadores/teste-reteste indeterminado.


Subject(s)
Humans , Male , Middle Aged , Aged , Activities of Daily Living , Surveys and Questionnaires , Pulmonary Disease, Chronic Obstructive/physiopathology , Translating , Severity of Illness Index , Reproducibility of Results , Cultural Characteristics
SELECTION OF CITATIONS
SEARCH DETAIL